Harbourline Hotels
DemoViewing asYou can try everything, but nothing you change is saved.
Environment

Energy

Everything about the energy the property buys and how efficiently it uses it: total consumption from bills (ENV-01), the renewable share (ENV-02), year-on-year change (ENV-03), LED coverage (ENV-04), efficiency equipment and controls (ENV-05) and low-impact refrigerants (ENV-06).

Why it matters. Energy is usually the biggest controllable cost after payroll and the largest part of your carbon footprint. It is the first thing every scheme and corporate buyer asks about, and the one where the business case is easiest to prove.

Energy score
55
of 100
Comparison 68Enter data
Charts

Energy · per occupied room-night by month

Report by
to··
Energy consumptionENV-01
kWh per occupied room-night · range total 534,342 kWh · target 25
Score
74
0204060Jan: 55.9 kWh (estimated)JanFeb: 57.1 kWhFebMar: 50.4 kWhMarApr: 54.5 kWhAprMay: 54.7 kWhMayJun: 49.7 kWhJunJul: 51.7 kWhJulAug: 58.3 kWhAugSep: 57.1 kWhSepOct: 55.7 kWhOctNov: 52 kWh (draft)Novtarget
By meter / source / stream · share of range total · dashed = sub-meter or record only, not added
Renewable electricityENV-02
% · target 100
Score
50
0102030Jan: 28.6 %JanFeb: 28.6 %FebMar: 28.6 %MarApr: 28.6 %AprMay: 28.6 %MayJun: 28.6 %JunJul: 28.6 %JulAug: 28.6 %AugSep: 28.6 %SepOct: 28.6 %OctNov: 28.6 %Novtarget
Year-on-year energy reductionENV-03
% · target 5
Score
69
00.511.52Jan: 1.7 %JanFeb: 1.7 %FebMar: 1.7 %MarApr: 1.7 %AprMay: 1.7 %MayJun: 1.7 %JunJul: 1.7 %JulAug: 1.7 %AugSep: 1.7 %SepOct: 1.7 %OctNov: 1.7 %Novtarget
Efficient lightingENV-04
% · target 100
Score
35
020406080Jan: 78.5 %JanFeb: 78.5 %FebMar: 78.5 %MarApr: 78.5 %AprMay: 78.5 %MayJun: 78.5 %JunJul: 78.5 %JulAug: 78.5 %AugSep: 78.5 %SepOct: 78.5 %OctNov: 78.5 %Novtarget

Readings stay as entered and are spread evenly across their days, then re-added into months. Solid = submitted · faded = mostly estimated · dashed = draft · line = target. Breakdowns are one line per meter, fuel, source or stream; carbon is derived by scope.

Show entered data (152 records this year)
Energy consumptionENV-01FoundationalGuide (PDF)
Energy used per source series (grid electricity, gas, LPG, oil, diesel, district heat, on-site solar), entered in native units or cost, normalised to kWh; export netted off · evidence: Utility bill / fuel invoice
kWh / room-night
59.12
Baseline 2025 (=0)
65.87
Target (=100)
59.28
Floor (=0)
90
Score
74
PeriodValueStatusEvidenceCaptured
Nov 2026Main electricity meter19,498Draftnone attached19/11/2026
Nov 2026Kitchen sub-meter3,825Draftnone attached19/11/2026
Nov 2026Gas (boilers & kitchen)1,364.1 m³ = 14,391 kWhDraftnone attached19/11/2026
Oct 2026Gas (boilers & kitchen)1,478.6 m³ = 15,599 kWhSubmittedgas-boilers-kitchen--2026-10.pdf (self)07/11/2026
Oct 2026Main electricity meter23,645Submittedmain-electricity-meter-2026-10.pdf (self)07/11/2026
Oct 2026Kitchen sub-meter4,463Submittedkitchen-sub-meter-2026-10.pdf (self)05/11/2026
… 27 more this year
Renewable electricityENV-02Guide (PDF)
% of electricity from renewable sources, with the tariff or contract · evidence: Supplier contract / certificate
%
28.6
Baseline 2025 (=0)
25.53
Target (=100) · default 5%
26.81
Floor (=0)
0
Score
50
PeriodValueStatusEvidenceCaptured
202628.6Submittednone attached19/11/2026
Year-on-year energy reductionENV-03
% change in energy use vs the prior year, like-for-like · evidence: Derived from bills
%
1.7
Baseline 2025 (=0)
1.5
Target (=100) · default 5%
1.57
Floor (=0)
-5
Score
69
PeriodValueStatusEvidenceCaptured
20261.7Submittednone attached19/11/2026
Efficient lightingENV-04Guide (PDF)
% of guest and public-area lighting that is LED · evidence: Lighting audit / photos
%
78.5
Baseline 2025 (=0)
72.57
Target (=100) · default 5%
76.2
Floor (=0)
80
Score
35
PeriodValueStatusEvidenceCaptured
202678.5Submittednone attached19/11/2026
Efficiency equipment & controlsENV-05Guide (PDF)
Keycard switches, efficient appliances, smart thermostats, insulation, glazing; coil and filter cleaning schedule · evidence: Document / photo
In place
Yes
Score
100
PeriodValueStatusEvidenceCaptured
2026YesReviewedENV-05-policy.pdf (internal)19/11/2026
Low-impact refrigerantsENV-06Guide (PDF)
Cooling uses natural or low-GWP refrigerants and is HFC-free · evidence: Equipment spec / service record
In place
No
Score
0
PeriodValueStatusEvidenceCaptured
2026NoReviewednone attached19/11/2026
How to track this well
  1. 1List every meter and fuel account on site: main incomers, sub-meters, gas, LPG, oil tank, generator diesel.
  2. 2Each month enter each bill against its own meter or fuel, in the unit printed on it (kWh, m³, litres) and for the exact period on the bill; Canoprise converts it to kWh, splits it across months and divides by occupied room-nights.
  3. 3Attach the bill. When a bill is late, enter a meter photo as an estimated read and true it up later.
  4. 4Once a year confirm the renewable share from your supply contract, the LED percentage from a quick lighting walk-round, and tick off the efficiency controls that are in place.
  5. 5Review flagged readings: anything more than double or less than half your usual is held back until confirmed.
Where the data comes from
  • · Utility bills (electricity, gas)
  • · Fuel delivery invoices (LPG, oil, diesel)
  • · Supply contract or renewable certificates
  • · Lighting and equipment walk-round
  • · BMS export if you have one
Evidence to attach

Bill or invoice PDF per period; supply contract; photos from the lighting audit; refrigerant service records.

Cadence and owner

Consumption monthly (chief engineer or finance, about 15 minutes once bills arrive); the rest annually or when something changes.

Common pitfalls
  • · Entering the invoice date instead of the consumption period
  • · Missing a sub-meter or fuel account, which makes the total look better than it is
  • · Forgetting occupancy, which leaves the intensity blank
  • · Entering a gas or LPG bill against the electricity meter instead of its own line
Quick wins that move the score
  • · Finish the LED retrofit in back-of-house
  • · Set-back temperatures for unoccupied rooms
  • · A coil and filter cleaning schedule for HVAC
Readiness checklist
3 of 6 attributes up to date
  • Energy consumptionENV-01Monthly
    Energy used per source series (grid electricity, gas, LPG, oil, diesel, district heat, on-site solar), entered in native units or cost, normalised to kWh; export netted off
    Up to date · 33 records this year
    3 data points to enter, 2 derived
    • ENV-01.1Energy used, per seriesone row per meter / fuel · kWh / MWh / m³ / L / kg / GJ / therm → kWh · GK 4.1 · GSTC D1 · WTTC #1
    • ENV-01.2Energy cost, per seriesmoney
    • ENV-01.3Measurement method statementdoc · GK 4.1
    • ENV-01.4Total energy (Σ series − export)derived, nothing to enter
    • ENV-01.5Energy intensity per occupied room-nightderived, nothing to enter
  • !
    % of electricity from renewable sources, with the tariff or contract
    Attach evidence (supplier contract / certificate) · 1 record this year
    4 data points to enter, 1 derived
    • ENV-02.1Renewable share of electricity (tariff / contract)pct · GK 4.6/4.7 · GSTC D1
    • ENV-02.2Renewable share of heating & coolingpct · GK 4.4/4.5
    • ENV-02.3Supplier contract / guarantee of origindoc · GK 4.6
    • ENV-02.4Renewable share incl. on-site generationderived, nothing to enter
    • ENV-02.5Supplier emission factor for electricity (market-based)count · GRI 305-2 · CSRD E1
  • % change in energy use vs the prior year, like-for-like
    Derived from this year's and last year's energy intensity — nothing to enter · 1 record this year
    1 data point to enter, 1 derived
    • ENV-03.1Year-on-year change in energy intensityderived, nothing to enter
    • ENV-03.2Like-for-like adjustment notetext
  • !
    Efficient lightingENV-04Annual
    % of guest and public-area lighting that is LED
    Attach evidence (lighting audit / photos) · 1 record this year
    4 data points to enter
    • ENV-04.1LED share of light pointspct · GK 4.14 (≥80%)
    • ENV-04.2LED light pointscount
    • ENV-04.3Total light pointscount
    • ENV-04.4Lighting inventory / invoicesdoc
  • Keycard switches, efficient appliances, smart thermostats, insulation, glazing; coil and filter cleaning schedule
    Up to date · 1 record this year
    8 data points to enter
    • ENV-05.1Efficiency measures in placebool
    • ENV-05.2Set-point SOP documentedbool · GK 4.2
    • ENV-05.3Switch-off procedure or automationbool · GK 4.3
    • ENV-05.4HVAC maintained in last 12 monthsdate · GK 4.13
    • ENV-05.5Coil & filter cleaning schedulebool · WTTC 2026
    • ENV-05.6New electronics energy-ratedbool · GK 4.16
    • ENV-05.7Energy audit in last 6 yearsdate · GK 4.9 (G)
    • ENV-05.8Sub-meters at key pointsbool · GK 4.11 (G)
  • !
    Cooling uses natural or low-GWP refrigerants and is HFC-free
    Attach evidence (equipment spec / service record) · 1 record this year
    3 data points to enter
    • ENV-06.1HFC-free / low-GWP coolingbool
    • ENV-06.2Refrigerant top-up, per gasone row per series · kg → kg · GSTC D3 (Scope 1)
    • ENV-06.3Refrigerant inventory (type, charge)doc