Energy
Everything about the energy the property buys and how efficiently it uses it: total consumption from bills (ENV-01), the renewable share (ENV-02), year-on-year change (ENV-03), LED coverage (ENV-04), efficiency equipment and controls (ENV-05) and low-impact refrigerants (ENV-06).
Why it matters. Energy is usually the biggest controllable cost after payroll and the largest part of your carbon footprint. It is the first thing every scheme and corporate buyer asks about, and the one where the business case is easiest to prove.
Energy · per occupied room-night by month
Readings stay as entered and are spread evenly across their days, then re-added into months. Solid = submitted · faded = mostly estimated · dashed = draft · line = target. Breakdowns are one line per meter, fuel, source or stream; carbon is derived by scope.
Show entered data (238 records this year)Hide entered data
| Period | Value | Status | Evidence | Captured |
|---|---|---|---|---|
| Nov 2026Backup generator diesel | 1,085.4 L = 11,614 kWh | Draft | none attached | 19/11/2026 |
| Nov 2026Kitchen sub-meter | 18,265 | Draft | none attached | 19/11/2026 |
| Nov 2026Rooftop solar PV | 19,308 | Draft | none attached | 19/11/2026 |
| Nov 2026Kitchen & boiler LPG | 7,746.9 L = 54,848 kWh | Draft | none attached | 19/11/2026 |
| Nov 2026Main electricity meter | 90,777 | Draft | none attached | 19/11/2026 |
| Oct 2026Kitchen & boiler LPG | 7,270.2 L = 51,473 kWh | Submitted | kitchen-boiler-lpg-2026-10.pdf (self) | 09/11/2026 |
| … 49 more this year | ||||
| Period | Value | Status | Evidence | Captured |
|---|---|---|---|---|
| 2026 | 33.1 | Submitted | none attached | 19/11/2026 |
| Period | Value | Status | Evidence | Captured |
|---|---|---|---|---|
| 2026 | 2.1 | Submitted | none attached | 19/11/2026 |
| Period | Value | Status | Evidence | Captured |
|---|---|---|---|---|
| 2026 | 87.7 | Submitted | none attached | 19/11/2026 |
| Period | Value | Status | Evidence | Captured |
|---|---|---|---|---|
| 2026 | Yes | Reviewed | ENV-05-policy.pdf (internal) | 19/11/2026 |
| Period | Value | Status | Evidence | Captured |
|---|---|---|---|---|
| 2026 | Yes | Reviewed | ENV-06-policy.pdf (internal) | 19/11/2026 |
- 1List every meter and fuel account on site: main incomers, sub-meters, gas, LPG, oil tank, generator diesel.
- 2Each month enter each bill against its own meter or fuel, in the unit printed on it (kWh, m³, litres) and for the exact period on the bill; Canoprise converts it to kWh, splits it across months and divides by occupied room-nights.
- 3Attach the bill. When a bill is late, enter a meter photo as an estimated read and true it up later.
- 4Once a year confirm the renewable share from your supply contract, the LED percentage from a quick lighting walk-round, and tick off the efficiency controls that are in place.
- 5Review flagged readings: anything more than double or less than half your usual is held back until confirmed.
- · Utility bills (electricity, gas)
- · Fuel delivery invoices (LPG, oil, diesel)
- · Supply contract or renewable certificates
- · Lighting and equipment walk-round
- · BMS export if you have one
Bill or invoice PDF per period; supply contract; photos from the lighting audit; refrigerant service records.
Consumption monthly (chief engineer or finance, about 15 minutes once bills arrive); the rest annually or when something changes.
- · Entering the invoice date instead of the consumption period
- · Missing a sub-meter or fuel account, which makes the total look better than it is
- · Forgetting occupancy, which leaves the intensity blank
- · Entering a gas or LPG bill against the electricity meter instead of its own line
- · Finish the LED retrofit in back-of-house
- · Set-back temperatures for unoccupied rooms
- · A coil and filter cleaning schedule for HVAC
- Energy used per source series (grid electricity, gas, LPG, oil, diesel, district heat, on-site solar), entered in native units or cost, normalised to kWh; export netted offUp to date · 55 records this year
3 data points to enter, 2 derived
- ENV-01.1Energy used, per seriesone row per meter / fuel · kWh / MWh / m³ / L / kg / GJ / therm → kWh · GK 4.1 · GSTC D1 · WTTC #1
- ENV-01.2Energy cost, per seriesmoney
- ENV-01.3Measurement method statementdoc · GK 4.1
- ENV-01.4Total energy (Σ series − export)derived, nothing to enter
- ENV-01.5Energy intensity per occupied room-nightderived, nothing to enter
- !% of electricity from renewable sources, with the tariff or contractAttach evidence (supplier contract / certificate) · 1 record this year
4 data points to enter, 1 derived
- ENV-02.1Renewable share of electricity (tariff / contract)pct · GK 4.6/4.7 · GSTC D1
- ENV-02.2Renewable share of heating & coolingpct · GK 4.4/4.5
- ENV-02.3Supplier contract / guarantee of origindoc · GK 4.6
- ENV-02.4Renewable share incl. on-site generationderived, nothing to enter
- ENV-02.5Supplier emission factor for electricity (market-based)count · GRI 305-2 · CSRD E1
- % change in energy use vs the prior year, like-for-likeDerived from this year's and last year's energy intensity — nothing to enter · 1 record this year
1 data point to enter, 1 derived
- ENV-03.1Year-on-year change in energy intensityderived, nothing to enter
- ENV-03.2Like-for-like adjustment notetext
- !% of guest and public-area lighting that is LEDAttach evidence (lighting audit / photos) · 1 record this year
4 data points to enter
- ENV-04.1LED share of light pointspct · GK 4.14 (≥80%)
- ENV-04.2LED light pointscount
- ENV-04.3Total light pointscount
- ENV-04.4Lighting inventory / invoicesdoc
- Keycard switches, efficient appliances, smart thermostats, insulation, glazing; coil and filter cleaning scheduleUp to date · 1 record this year
8 data points to enter
- ENV-05.1Efficiency measures in placebool
- ENV-05.2Set-point SOP documentedbool · GK 4.2
- ENV-05.3Switch-off procedure or automationbool · GK 4.3
- ENV-05.4HVAC maintained in last 12 monthsdate · GK 4.13
- ENV-05.5Coil & filter cleaning schedulebool · WTTC 2026
- ENV-05.6New electronics energy-ratedbool · GK 4.16
- ENV-05.7Energy audit in last 6 yearsdate · GK 4.9 (G)
- ENV-05.8Sub-meters at key pointsbool · GK 4.11 (G)
- Cooling uses natural or low-GWP refrigerants and is HFC-freeUp to date · 1 record this year
3 data points to enter
- ENV-06.1HFC-free / low-GWP coolingbool
- ENV-06.2Refrigerant top-up, per gasone row per series · kg → kg · GSTC D3 (Scope 1)
- ENV-06.3Refrigerant inventory (type, charge)doc