Carbon footprint · Scopes 1, 2 and 3
Scope 1 is fuel burned and refrigerant lost on site. Scope 2 is bought electricity and heat. Scope 3 here is calculated from the waste, water and energy figures you already record, plus the staff commute survey: it covers four of the supply-chain categories, not all of them, and is not part of the score.
Scope 2, market-based: 832 t. Bought electricity less the renewable share on your tariff, at the supplier’s factor where you have recorded one, otherwise at the grid average. Report both figures; GRI 305-2 and CSRD E1 ask for each.
Removals: 40 t
Bought, not yet retired: 60 t (not counted)
Credits are shown beside the footprint and are never taken off it. The footprint above is what the group emitted. Do not describe a stay or the business as carbon neutral, net zero or climate positive on the strength of credits. See the credits
Waste Category 5: waste generated in operations · from waste by stream | 67 t | 12% |
Water supply and treatment Categories 1 and 5 by convention · from water consumption | 38 t | 7% |
Producing and delivering energy Category 3: fuel- and energy-related activities · from gas and electricity used | 434 t | 80% |
Staff commuting Category 7: employee commuting · from the commute survey | 0 t | 0% |
Business travel Category 6 · from the travel log · 8.1 t with the altitude effects of flying | 5 t | 1% |
| Property | Scope 1 | Scope 2 | Waste | Water | Energy supply | Travel | Commuting | Total | kg per room-night |
|---|---|---|---|---|---|---|---|---|---|
| Anchor Inn Cork* | 37 | 87 | 3.2 | 1.7 | 23 | – | – | 151 | 15.3 |
| Anchor Inn Glasgow | 36 | 59 | 2.8 | 1.7 | 22 | 0 | – | 122 | 10.3 |
| Anchor Inn Leeds | 45 | 74 | 3.9 | 2.2 | 27 | – | – | 152 | 10.9 |
| Harbourline Grand | 96 | 170 | 8.3 | 4.5 | 58 | 0.4 | – | 336 | 7.6 |
| Harbourline Links Golf* | 83 | 68 | 3.4 | 1.2 | 22 | – | – | 178 | 14.5 |
| Harbourline Lisbon* | 71 | 85 | 5.6 | 3.2 | 28 | – | – | 193 | 5.5 |
| Harbourline Marbella Resort* | 190 | 180 | 12 | 8 | 66 | 4.2 | – | 461 | 10.2 |
| Harbourline Spa Marbella* | 38 | 44 | 3.1 | 1.7 | 16 | – | – | 103 | 8.4 |
| The Quayside | 77 | 137 | 6.4 | 3.6 | 47 | – | – | 272 | 9.8 |
| Tideway Bristol | 57 | 93 | 4.3 | 2.6 | 34 | – | – | 191 | 8.3 |
| Tideway Dublin* | 46 | 107 | 3.9 | 2.2 | 28 | – | – | 187 | 8.6 |
| Tideway Manchester | 73 | 127 | 6.1 | 3.1 | 44 | 0.3 | – | 253 | 10.2 |
| Tideway Porto* | 45 | 60 | 3.9 | 1.9 | 19 | – | – | 130 | 8.5 |
| What | Spain | Ireland | Portugal | United Kingdom | Unit | Source of the UK figure |
|---|---|---|---|---|---|---|
| Waste sent to landfill | 520.3 (UK) | 520.3 (UK) | 520.3 (UK) | 520.3 | kgCO2e per tonne | DESNZ, commercial and industrial waste to landfill (2024 edition figure) · to be checked |
| Waste recycled | 6.411 (UK) | 6.411 (UK) | 6.411 (UK) | 6.411 | kgCO2e per tonne | DESNZ 2025, recycling (collection and transport only; assumed equal to combustion) · to be checked |
| Food and organic waste composted or digested | 8.9 (UK) | 8.9 (UK) | 8.9 (UK) | 8.9 | kgCO2e per tonne | DESNZ, organic waste composting or anaerobic digestion (earlier edition figure) · to be checked |
| Water supplied | 0.1913 (UK) | 0.1913 (UK) | 0.1913 (UK) | 0.1913 | kgCO2e per m³ | DESNZ 2025, water supply · to be checked |
| Waste water treated | 0.186 (UK) | 0.186 (UK) | 0.186 (UK) | 0.186 | kgCO2e per m³ | DESNZ, water treatment (2024 edition figure; 2025 reported no major change) · to be checked |
| Producing and delivering natural gas | 0.03021 (UK) | 0.03021 (UK) | 0.03021 (UK) | 0.03021 | kgCO2e per kWh (gross) | DESNZ, well-to-tank, natural gas · to be checked |
| Producing the fuel burned to generate electricity | 0.03682 (UK) | 0.03682 (UK) | 0.03682 (UK) | 0.03682 | kgCO2e per kWh | DESNZ, well-to-tank, UK electricity generation · to be checked |
| Electricity lost in the grid before it arrives | 0.0185 (UK) | 0.0185 (UK) | 0.0185 (UK) | 0.0185 | kgCO2e per kWh | DESNZ, UK electricity transmission and distribution losses (approximate) · to be checked |
Scope 1 and 2 use the factors already in Canoprise (location-based electricity per country), which are also placeholders to be replaced with the group’s chosen set. Sub-meters and record-only meters are not added. Values held for checking are left out.